TFOI
CU/XLPE/BED/CWB/HF
Application:
Used in the ships for instrumentation and communication. Also can be used for other indoor and outdoor.
Standard:
IEC 60092-376 Design guidelines
IEC 60228 Conductor
IEC 60092-360 Insulation & sheath
IEC 60332-1-2 Flame retardant properties
IEC 60332-3-22 Flame retardant properties
IEC 60754-1,2 Halogen free properties
IEC 61034-1,2 Smoke emission properties
Construction:
Conductor: Plain or tinned annealed copper, IEC 60228 class 2 or class 5.
Insulation: Halogen free cross-linked polyethylene XLPE, IEC 60092-360.
Laying up: Laying up of pairs/triples/quads.
Bedding: Flame retardant halogen free polyolefin compound, extruded or lapped.
Armour: Plain or tinned copper wire braid.
Outer sheath: Flame retardant halogen free polyolefin compound, SHF1,IEC 60092-360
Electrical Characteristics:
Capacitance, nom. 800Hz. 24.5
Loop Inductance, nom. 0.7
Insulation Resistance at 20°C ≥3670 MOhm.km
Pair Identification:
The pairs have the following number identification:
Pair no. 1 core no. 1 & 2
Pair no. 2 core no. 3 & 4
Pair no. 3 core no. 5 & 6
Pair no. 4 etc.
Triple cable is identified with no. 1, 2 and 3.
Quad cable has the following identification.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
TFOI(c)
CU/XLPE/OSCR/BED/CWB/HF
Application:
Used in the ships for instrumentation and communication. Also can be used for other indoor and outdoor applications.
Standard:
IEC 60092-376 Design guidelines
IEC 60228 Conductor
IEC 60092-360 Insulation & sheath
IEC 60332-1-2 Flame retardant properties
IEC 60332-3-22 Flame retardant properties
IEC 60754-1,2 Halogen free properties
IEC 61034-1,2 Smoke emission properties
Construction:
Conductor: Plain or tinned annealed copper, IEC 60228 class 2 or class 5.
Insulation: Halogen free cross-linked polyethylene XLPE, IEC 60092-360.
Laying up: Laying up of pairs/triples/quads.
Screen: Collective screen (Al/PET + tinned copper drain wire)
Bedding: Flame retardant halogen free polyolefin compound, extruded or lapped.
Armour: Plain or tinned copper wire braid.
Outer sheath: Flame retardant halogen free polyolefin compound, SHF1,IEC 60092-360
Electrical Characteristics:
Capacitance, nom. 800Hz. 24.5
Loop Inductance, nom. 0.7
Insulation Resistance at 20°C ≥3670 MOhm.km
Pair Identification:
The pairs have the following number identification:
Pair no. 1 core no. 1 & 2
Pair no. 2 core no. 3 & 4
Pair no. 3 core no. 5 & 6
Pair no. 4 etc.
Triple cable is identified with no. 1, 2 and 3.
Quad cable has the following identification.
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
TFOI(i&c)
CU/XLPE/ISCR/OSCR/BED/CWB/HF
Application:
Used in the ships for instrumentation and communication. Also can be used for other indoor and outdoor applications.
Standard:
IEC 60092-376 Design guidelines
IEC 60228 Conductor
IEC 60092-360 Insulation & sheath
IEC 60332-1-2 Flame retardant properties
IEC 60332-3-22 Flame retardant properties
IEC 60754-1,2 Halogen free properties
IEC 61034-1,2 Smoke emission properties
Construction:
Conductor: Plain or tinned annealed copper, IEC 60228 class 2 or class 5.
Insulation: Halogen free cross-linked polyethylene XLPE, IEC 60092-360.
Screen: Individual screen (Al/PET + tinned copper drain wire)
Laying up: Laying up of pairs/triples/quads.
Screen: Collective screen (Al/PET + tinned copper drain wire)
Bedding: Flame retardant halogen free polyolefin compound, extruded or lapped.
Armour: Plain or tinned copper wire braid.
Outer sheath: Flame retardant halogen free polyolefin compound, SHF1,IEC 60092-360
Electrical Characteristics:
Capacitance, nom. 800Hz. 24.5
Loop Inductance, nom. 0.7
Insulation Resistance at 20°C ≥3670 MOhm.km
Pair Identification:
The pairs have the following number identification:
Pair no. 1 core no. 1 & 2
Pair no. 2 core no. 3 & 4
Pair no. 3 core no. 5 & 6
Pair no. 4 etc.
Triple cable is identified with no. 1, 2 and 3.
Quad cable has the following identification.